Flowserve 3 Series P6 Type Kämmer Pneumatic Actuator Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Flowserve 3 Series P6 Type Kämmer Pneumatic Actuator. Flowserve 3 Series P6 Type Kämmer Pneumatic Actuator User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
1
1
Flow Control Division
Kammer Control Valves
Installation, Operation, Maintenance Instructions
Pneumatic Diaphragm On-Off Actuators
Series 3, Type: P6
1 USING KÄMMER VALVES AND ACTUATORS
CORRECTLY
1.1 General
The following instructions are designed to assist in
unpacking, installing and performing maintenance as
required on Kämmer products. Product users and
maintenance personnel should thoroughly review this
bulletin prior to installing, operating or performing
any maintenance.
DANGER:
In most cases Kämmer valves and actuators
are designed for specific applications (e.g. with regard
to medium, pressure, temperature). For this reason
they should not be used in other applications without
first contacting the manufacturer.
1.2 Terms concerning safety
The safety terms DANGER, WARNING, CAUTION and
NOTE are used in these instructions to highlight
particular dangers and/or to provide additional infor-
mation on aspects that may not be readily apparent.
DANGER:
indicates that death, severe personal injury
and/or substantial property damage will occur if proper
precautions are not taken.
WARNING:
indicates that death, severe personal in-
jury and/or substantial property damage can occur if
proper precautions are not taken
.
CAUTION:
indicates that minor personal injury and/or
property damage can occur if proper precautions are
not taken.
Index
1 Using Kämmer valves and actuators correctly.
2Unpacking
3 Installation
4 Quick check
5 Maintenance
6 Remove and install actuator
7 Disassemble actuator
8 Assemble actuator
9 Reverse actuator action
10 Troubleshooting chart
NOTE:
indicates and provides additional technical
information, which may not be very obvious even to
qualified personnel.
Compliance with other, not particularly emphasised
notes, with regard to transport, assembly, operation
and maintenance and with regard to technical docu-
mentation (e.g. in the operating instruction, product
documentation or on the product itself) is essential, in
order to avoid faults, which in themselves might
directly or indirectly cause severe personal injury or
property damage.
1.3 Protective clothing
Kämmer products are often used in problematic ap-
plications (e.g. extremely high pressures, dang-erous,
toxic or corrosive mediums). In particular valves with
bellows seals point to such applications. When per-
forming service, inspection or repair operations al-
ways ensure, that the valve and actuator are depres-
surised and that the valve has been cleaned and is free
from harmful substances. In such cases pay particu-
lar attention to personal protection (protective cloth-
ing, gloves, glasses etc.).
1.4 Qualified personnel
Qualified personnel are people who, on account of
their training, experience and instruction and their
knowledge of relevant standards, specifications, acci-
dent prevention regulations and operating condi-
tions, have been authorised by those responsible for
the safety of the plant to perform the necessary work
and who can recognise and avoid possible dangers.
1.5 Installation
DANGER:
Before installation check the order-no, se-
rial-no. and/or the tag-no. to ensure that the valve/
actuator is correct for the intended application.
Do not insulate extensions that are provided for hot or
cold services.
Pipelines must be correctly aligned to ensure that the
valve is not fitted under tension.
STOP!
KMEIM0004-00 - 08.03
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Series 3, Type: P6

111Flow Control DivisionKammer Control ValvesInstallation, Operation, Maintenance InstructionsPneumatic Diaphragm On-Off ActuatorsSeries 3, Type: P61

Page 2 - Flow Control Division

2Flow Control DivisionKammer Control Valves2 UNPACKING2.1 Each delivery includes a packing slip. Whenunpacking, check all delivered valves and accesso

Page 3

333Flow Control DivisionKammer Control Valves(for pneumatic positioners, 0.2 - 1.0 bar orcorresponding split-range values; for IP positioners,4-20 or

Page 4

4Flow Control DivisionKammer Control ValvesFig. 1: On-Off actuator, Air-to-Open1 Pre-tension plate2 Grooved pin, Ø 5 x 253 Diaphragm plate4 Diaphragm5

Page 5 - Fig. 2: Coupling

555Flow Control DivisionKammer Control Valves6.1 REMOVE ACTUATOR FROM VALVE BODY(refer to Figs. 1 + 2)6.1.1 Shut off the air supply.WARNING: Depressur

Page 6

6Flow Control DivisionKammer Control ValvesFig. 1: On-Off actuator, Air-to-Open1 Pre-tension plate2 Grooved pin, Ø 5 x 253 Diaphragm plate4 Diaphragm5

Page 7

777Flow Control DivisionKammer Control Valves8 ASSEMBLE THE ACTUATOR(see Figs. 1 + 2)8.1 Assemble diaphragm housing8.1.1 Fit bushing (11) and wiper ri

Page 8 - 10 Troubleshooting chart

8Flow Control DivisionKammer Control Valves10 Troubleshooting chartProblem Possible cause Corrective ActionStem pulsates 1. Unstable air supply 2. Adj