Flowserve BGM Dura Seal Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Flowserve BGM Dura Seal. Flowserve BGM Dura Seal User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation
Instructions
Experience In Motion
BGM Dura Seal
The Flowserve BGM
Dura Seal
is designed to keep bearing lubricant in the bearing frame. At
the same time, it keeps contamination out of the bearing frame. The BGM
Dura Seal
consists
of two major components: a stator assembly and a rotor assembly. The seals work in
conjunction with a "bull's-eye" sight gauge to completely isolate the bearing frame from
harmful contamination.
Temperature changes in the bearing housing will result in pressure fluctuations. Conventional
"constant level" oilers are not recommended. They are intolerant of such small pressure
changes.
Atmospheric Sealing of Bearing Frame
To isolate the bearing frame from environmental conditions such as high humidity, steam or
condensation, the following steps must be taken before seal assembly.
1. Remove bearing housing vents. They are a path for contamination.
2. Plug each vent.
3. Remove the "constant level" oiler
and replace it with a "bulls eye"
sight gauge. See Figure 1.
A minimum
3
/
8
" - 18 NPT tapped
hole must be provided to
accommodate the sight gauge.
4. When applying on equipment
using oil mist lubrication, provisions
must be made to allow oil mist flow
through the bearing housing.
Plug Vent
"Bulls Eye"
Sight Gauge
BGM
Dura Seal
Remove
"Constant Level"
Oiler
Stator Installation Figure 1
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Instructions

InstallationInstructionsExperience In MotionBGM Dura SealThe Flowserve BGM Dura Seal is designed to keep bearing lubricant in the bearing frame. Atth

Page 2

Stator Assembly InstallationThe stator assembly, consisting of the stator and the stator mounting ring, can be installedusing either an arbor press or

Page 3 - Rotor Assembly Installation

Rotor Assembly Installation1. Lightly lubricate the rotor O-ring inside diameter with the silicone grease provided withthe BGM Dura Seal.2. Break the

Page 4 - TO REORDER REFER TO

TO REORDER REFER TOB/M #F.O.To find your local Flowserve representativeand find out more about Flowserve Corporation,visit www.flowserve.comFIS170 REV

Commentaires sur ces manuels

Pas de commentaire