Installation InstructionsExperience In MotionSLM-6200 Self contained cartridge medium duty slurry seal
106.2 Remove the setting plate screws. With a screwdriver, pry the setting plates clear of the gland and remove them. Keep the setting plates and scr
117.2 Connect the seal gland barrier outlet (BO) port to the return side of the external system. 3/4” tubing is recommended for the seal circulation
TO REORDER REFER TOB/M #F.O.FIS159eng REV 7/13 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve Co
1 Cartridge Installation InstructionsThe following instruction manual is designed to simplify the installation of the SLM-6200 slurry seal. The SLM-6
32.4 Shaft radial runout should be less than 0.0005 mm per mm (0.0005 inch per inch) of shaft/sleeve diameter. See Figure 3. Turn the shaft through 3
42.6 Ensure that the shaft or shaft sleeve has a 1.6 mm (0.06 inch) x 30° chamfer on the leading edge to prevent O-ring damage at seal installation.2
53.6 For adapters provided with a centering jig, simply insert the centering jig into the adapter and tighten adapter bolts, alternately adjusting th
64.2 Seal chamber concentricity should be less than 0.38 mm (0.015 inch). See Figure 8. Seal life varies with alignment. Poor shaft alignment will re
7 4.7 Check the orientation of the gland ports and reposition as necessary. See Figure 6.4.8 Insert the retaining screws through the rear face of th
85.3 With the seal clamp collar facing toward the bearing assembly, slide the complete cartridge over the pump shaft/sleeve and push back toward the
9 5.9 Slide the seal cartridge up to the equipment case. Insert the gland retaining bolts through the gland holes and screw into the threaded holes o