FCD WCAIM2058-01
(Part 60130)
Worcester Actuation Systems
DataFlo Digital Electronic Remote Controller DRC-17
Installation, Operation and Maintenance Instructions
MODELS:
10 – For DataFlo Remote Controller and 10-23 75 Actuators
25 – For DataFlo Remote Controller and 25/30 75 Actuators
Setpoint Inputs:
DRC17-1K 1000 ohm Resistance Setpoint Input
DRC17-13 135 ohm Resistance Setpoint Input
DRC17-1 1 to 5 milliamp Setpoint Input
DRC17-4 4 to 20 milliamp Setpoint Input
DRC17-10 10 to 50 milliamp Setpoint Input
DRC17-5V 0 to 5 VDC Setpoint Input
DRC17-XV 0 to 10 VDC Setpoint Input
Voltages:
120A – 120 VAC Power Circuits
240A – 240 VAC Power Circuits
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Worcester Actuation Systems

FCD WCAIM2058-01(Part 60130)Worcester Actuation Systems DataFlo Digital Electronic Remote Controller DRC-17Installation, Operation and Maintenance Ins

Page 2 - TABLE OF CONTENTS

10 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Flow Control Worcester Actuation SystemsPower and Control Signal Wiring240 VAC ModelsFi

Page 3 - 1.0 General

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 113.1 Wiring the DRC Motor Driver BoardIn the following instructions, the “rear” side of

Page 4 - Board into Series 75 Actuator

12 DataFlo Digital Electronic Remote Controller DRC17 WCAIM20583.3.2 Wiring for a Potentiometer Setpoint (DRC17 – K – x – x – xxx)Refer to Figure 8 an

Page 5

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 133.3.6 Serial Communications WiringIn these steps, the DRC is shown attached to an RS-48

Page 6 - Flow Control

3.3.9 Position Feedback Output Wiring (applies to optionalmodule #19226 only)This output provides a current proportional to the positionof the valve s

Page 7

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 15This is the ENTER key. This key is used to accept an editedvalue. While viewing alarms

Page 8

16 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Alarm conditions may be cleared by pressing the ENT key.However, if the condition that

Page 9 - 120 VAC Models

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 17Table 2Parameter Minimum MaximumName Numeric Numeric ListDisplay Value Value Values Des

Page 10 - 240 VAC Models

18 DataFlo Digital Electronic Remote Controller DRC17 WCAIM20584.6.3 Setting Default Factory Parameter ValuesPress either the  or  key until the par

Page 11

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 194.6.4 DRC Programmable Parameter DefinitionsParameter Display DefinitionSecurity Code S

Page 12

2 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Flow Control Worcester Actuation SystemsTABLE OF CONTENTS1.0 GENERAL 31.1 Important Item

Page 13

20 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Parameter Display DefinitionPower-On Position Pon Posn Position the shaft will be drive

Page 14

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 21established in Program Mode (paragraph 4.6.2). Whenthe correct manual setpoint is displ

Page 15

22 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058When step 2 valve movement has completed, thedisplay will alternate between Step #2 and

Page 16

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 234.9.3 Calibration of Cycle TimeNOTE: This procedure should only be performed if thecloc

Page 17

24 DataFlo Digital Electronic Remote Controller DRC17 WCAIM20584.9.7 Calibration of an RTD Process InputNOTE: This procedure applies only if an RTD pr

Page 18

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 25Press ENT to begin the thermocouple calibrationprocedure. The display will show TC Type

Page 19

26 DataFlo Digital Electronic Remote Controller DRC17 WCAIM20585.9 Position/Control Select InputVoltage Range: 10 to 30 VDCMaximum Reverse Voltage: 5

Page 20

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 27Symptom TableSymptom Paragraphs to ReferenceActuator will not operate in either directi

Page 21

6.5.9 What to check: With power off and using a capacitancemeter, check the motor run capacitor for a short, forexcessively high leakage and for low c

Page 22

1.0 GeneralThe Worcester Actuation Systems Dataflo Remote Controller (DRC17)was designed for use with the Worcester Series 75 electric actuators.Howev

Page 23

4 DataFlo Digital Electronic Remote Controller DRC17 WCAIM20581.1.5 Storage ConditionsFlowserve recommends that all products that must bestored prior

Page 24

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 52.2 Mounting Potentiometer:2.2.1 Mounting Single Potentiometer into Series 75 Actuator(S

Page 25

6 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Flow Control Worcester Actuation Systems10-23 75Plan View25/30 75Plan ViewView A-AView B

Page 26 - 6.0 Troubleshooting

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 72.3.2 For 120/240 VAC 25 and 30 Size Electric Actuators: (See Figure 3.) A. Assemble cir

Page 27

8 DataFlo Digital Electronic Remote Controller DRC17 WCAIM2058Flow Control Worcester Actuation SystemsLimit Switch Locations(SW-3 and SW-4 are optiona

Page 28

WCAIM2058 DataFlo Digital Electronic Remote Controller DRC17 9Flow Control Worcester Actuation SystemsPower and Control Signal Wiring120 VAC ModelsFig

Commentaires sur ces manuels

Pas de commentaire