Worcester Actuation Systems
1. Description
The I-75 Interface is designed to be used and mounted in the Series
75 Actuator as one of many standard options. Function of the I-75
Interface is to allow the Series 75 Actuator to be powered by a 120 or
240 VAC power supply, operated directly by any programmable
controller, microprocessor, and/or computer regardless of the output
rating of these devices. Depending on the control input to be used,
there are several options of the I-75 Interface:
These options are identified by the nameplate on the circuit board.
5V for 5 VDC input
XV for 12 VDC input
XX for 24 VDC input
15 for 120 VAC input
2. Installation of I-75 Interface Board into
Series 75 Electric Actuator
2.1 Check Kit for Parts:
Common Parts for Sizes 10-30 Actuators
Qty. Name
1 Circuit Board Subassembly
1 Insulating Board
5-6 Washers (Nylon)
5-6 Grommets (Rubber)
5-6 Mounting Screws
5 Cable Ties
1 Wiring Label
1 Closed-End Splice
1 Wire - White
Additional Parts for Sizes 10-23 Actuators
Qty. Name
1 Bracket - Right
1 Bracket - Left
2 Spacer (Bracket)
2 Mounting Screw (Spacer/Bracket)
Additional Parts for 240 VAC Option
Qty. Name
2 Limit Switch
1 Lead Assembly - Gray
1 Lead Assembly - Blue
Additional Parts for Sizes 25, 30 Actuators
Qty. Name
1 Mounting Bracket
2 Mounting Screw (Bracket)
Tools needed for assembly:
1
/
4" Nut Driver,
1
/
8" Screwdriver and Needle Nose Pliers.
FCD WCAIM2000-00
(Part 06094)
I-75 Interface
Installation, Operation and Maintenance Instructions
Figure 1
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - I-75 Interface

Worcester Actuation Systems1. DescriptionThe I-75 Interface is designed to be used and mounted in the Series75 Actuator as one of many standard option

Page 2 - Worcester Actuation Systems

2Flow Control Worcester Actuation Systems2.2 Assembly Procedure2.2.1 For 10-23 Size Electric Actuators (See Figure 2):A. Pre-tap circuit board bracket

Page 3 - 3. Wiring

3Flow Control Worcester Actuation Systems3. Wiring3.1 External Power - 120/240 VAC Option (Figures 3 and 4):NOTE: All wiring to terminal strip should

Page 4 - 4. Indication and Repair

3.3.2 PC Board - 240 VAC (Figure 4):For I-75, 240 VAC option only, the limit switches (SW-1, SW-2)are used to interrupt CW, CCW input signals, therefo