Flowserve Limitorque QXM Linear Base Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
MXa/QXM Linear Base FCD LMENIM2315-00 – 6/14
4
1.1.2 Optional LB FA or EN (F) Base and Stop Nut Subassembly
NOTE: The EN (F) base meets standard DS/EN 15714-2 but has the same mounting as an ‘F’ ISO style base.
Step 1
(Optional Stop Nut if supplied) Remove set screw (#13) and spin nut (#12) off shaft.
NOTE: Optional nut may only be used when LB is mounted to a QXM, MX-10 or MX-40 actuator.
Step 2
(Optional FA/EN (F) base) Remove the four bolts (#11) that secure the optional base to the anti-rotation base (#1) and
slide the base off over shaft (#2) and bellows (#7).
Figure 1.2 – Optional LB FA/EN (F) Base and Stop Nut Subassembly
LB1 assembly shown in this figure.
Table 1.1 – Optional LB1 and LB2 Subassembly
ITEM NUMBER DESCRIPTION QTY. NOTES
1 ANTI-ROTATION BASE 1
2 SHAFT 1
3 THRUST NUT 1
PART OF THRUST BASE ASSEMBLY, BUT MACHINED
TO MATE WITH LB ASSEMBLY
4 SOCKET HEAD CAP SCREWS 4
5 THRUST BASE ASSEMBLY 1
6 GASKET 1
7 BELLOWS AND TWO CLAMPS 1
8 GREASE FITTING 1
9 PIPE PLUG 1
10 OPTIONAL FA OR EN (F) BASE 1
11 SOCKET HEAD CAP SCREWS 4
12 OPTIONAL STOP, HW CLOSED 1 QXM, MX-10 AND MX-40 ONLY
13 SET SCREW, OPTIONAL STOP 1 QXM, MX-10 AND MX-40 ONLY
14 ANTI-ROTATION NUT 1 LB2 ONLY
15 O-RING 1 LB2 ONLY
16-16 SPACER, PILOT 1 SEE NOTES FOR USAGE