Flowserve MX Dashboard Limitorque Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Flowserve MX Dashboard Limitorque. Flowserve MX Dashboard Limitorque User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
USER INSTRUCTIONS
LIMITORQUE MX/QX Dashboard
FCD LMENIM2338-01
Experience In Motion
Experience In Motion
Installation
Operation
Maintenance
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - USER INSTRUCTIONS

USER INSTRUCTIONSLIMITORQUE MX/QX Dashboard FCD LMENIM2338-01Experience In MotionExperience In MotionInstallationOperationMaintenance

Page 2

10FCD LMENIM2338-01This section describes the options and data available using the Dashboard application. Data includes Frequency Domain Analysis (FDA

Page 3 - Table of Contents

11FCD LMENIM2338-01Torque SetupAllowed changes: Torque % value from 40-100% [contact Limitorque before increasing torque values as the actuators are

Page 4

12FCD LMENIM2338-01Status and Alarm Configuration (Relay) OptionAllowed changes: S1-S2, R1-R8 – option dependent [allows for installed relay changes i

Page 5

13FCD LMENIM2338-01Local Control ConfigurationAllowed changes: Local Control Enable, LED color reversal. ESD (Emergency Shutdown) Overrides Configurat

Page 6 - MX/QX Configuration

14FCD LMENIM2338-01Reset Diagnostics OptionAllows for establishing a new baseline for the OPEN and CLOSE cycles. Unit Tag ConfigurationAllowed change

Page 7

15FCD LMENIM2338-01Motor Thermostat ConfigurationAllows for enabling or disabling motor over temperature protection [recommended setting is Enable Mot

Page 8 - Dashboard Offline Mode

16FCD LMENIM2338-01Backup Power ConfigurationIf equipped with this option, the recommended setting is to enable backup, power which allows for viewing

Page 9

17FCD LMENIM2338-01This section describes the diagnostics available via Dashboard.To access the diagnostics, a BT or IR Link must be established. Thi

Page 10 - MX/QX Configuration Detailed

18FCD LMENIM2338-01FDA is available on all MX/QX actuators supporting the BT option. The BT option is not necessary to obtain the FDA data. The data

Page 11 - FCD LMENIM2338-01

19FCD LMENIM2338-01Proceed to selecting “GET FDA” and the following screen should appear: Once the read completes, proceed with viewing the trace da

Page 12

This page was left blank intentionally.

Page 13

20FCD LMENIM2338-01Viewing Trace Data SelectingViewTraceDatawillresultinthefollowingdisplaypresuming valid collection of data. The FDA Trace

Page 14

21FCD LMENIM2338-01Analog Board Summary Status (MX/QX Option)If optional analog boards are installed, the operational status of the boards is display

Page 15

22FCD LMENIM2338-01Position EncoderThe MX/QX actuator utilizes a unique encoder design consisting of absolute and incremental encoders. The diagnosti

Page 16

23FCD LMENIM2338-01The Dashboard is provided with two utilities that allow for the MX/QX firmware update and detailed troubleshooting. The utilities c

Page 17 - MX/QX Diagnostics

24FCD LMENIM2338-01The Modsim utility allows for internal diagnostics of the MX/QX actuator. This option can be used with BT (if equipped) or the sta

Page 18

25FCD LMENIM2338-01This section details troubleshooting information associated with Dashboard to the MX/QX communication.Link Lost ErrorThis message

Page 19

26FCD LMENIM2338-01LMENIM2306 – MX Installation and Operation ManualLMENIM4019 – Direct to Host ManualLMENBR2300-00 – Technical Bulletin, Protection/C

Page 20

This page was left blank intentionally.

Page 21

flowserve.comflowserve.comFlowserve CorporationFlow ControlUnited StatesFlowserve Limitorque5114 Woodall Road, P.O. Box 11318Lynchburg,VA24506-1318Ph

Page 22

3FCD LMENIM2338-01Table of ContentsAbout MX/QX Dashboard Software 4Installing and Activating Dashboard 5MX/QX Configuration 6Creating the Dashboard

Page 23 - Additional Utilities

4FCD LMENIM2338-01The MX/QX is the non-intrusive intelligent actuator of choice for users demanding safety, quality, ease of configuration and technol

Page 24

5FCD LMENIM2338-01Dashboard is supported on the following computer systems:• PDA-MicrosoftMobile5or6operatingsystemonlywithBluetooth and I

Page 25 - Troubleshooting

6FCD LMENIM2338-01To configure the MX/QX “port” setting, refer to the LMEIM2306/3306 for detailed instructions.To use the MX/QX Downloader option on t

Page 26 - Supporting Documentation

7FCD LMENIM2338-01This document is designed to demonstrate the capabilities of the Bluetooth link for communication with the MX/QX. IR communication i

Page 27

8FCD LMENIM2338-01The Dashboard offline mode allows the user to configure the MX/QX configuration prior to the system upload. The user is allowed to c

Page 28 - flowserve.com

9FCD LMENIM2338-01This section describes the available configuration options applicable to the MX/QX. The below illustrations are applicable to the of