Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
78
4.13.1 Removal
First Remove
1. Remove actuator from mounting adapter.
2. Drain oil.
3. Remove top-mounted handwheel (#1-8). (See Section 4.3.1.)
4. Remove motor (subassembly #4). (See Section 4.1.1.)
5. Remove worm shaft (subassembly #3). (See Section 4.10.1.)
6. Remove base plate (subassembly #11). (See Section 4.9.1.)
7. Remove drive sleeve (subassembly #2). (See Section 4.11.1.)
STEP 1
c
WARNING: Potential to operate while dangerous mechanical parts are exposed during
subassembly removal. To prevent injury, turn off all power sources to actuator before
removing handwheel adapter assembly. Power sources may include main power or
control power.
Remove handwheel spacer (#1-9).
1
1-9
STEP 2
Unwind wave spring (#1-10) and remove.
2
1-10