Vue de la page 29
Flow Control
Nordstrom Valves
30 Dynamic Balance
®
Plug Valve and Double DB
®
Double Isolation Plug Valve FCD NVENIM2005-01
9 Tables
Torque Values for Pressure Retaining Bolting
Table 1– Size 4 and Smaller Valve Gland Bolting
Bolt Size 1st
Torque (ft-lb)
2nd 3rd
3
8 - 16 UNC Hand Snug 15 25
½ - 13 UNC Hand Snug 40 55
5
8 - 11 UNC Hand Snug 80 110
Table 2 – Size 4 and Smaller Valve Cover Bolting
Bolt Size
Torque (ft-lb)
1st 2nd 3rd
3
8 11 UNC 20 85 110
¾ – 10 UNC 20 135 180
7
8 9 UNC 30 220 290
1 – 8 UNC 45 340 450
1
1
8 8 UNC 70 530 705
1¼ – 8 UNC 90 675 900
Table 3 – Size 6 and Larger Valve Pressure Retaining Bolting
(all parts)
Thread Size
Torque (ft-lb)
Minimum Maximum
¼ – 20 5 6
5
16 - 18 10 12
3
8 16 15 18
7
16 – 14 25 30
½ – 13 38 45
9
16 – 12 58 68
5
8 11 76 90
¾ – 10 127 150
7
8 9 205 240
1 – 8 315 370
1
1
8 8 500 585
1¼ – 8 640 750
1
3
8 8 870 1020
1½ – 8 1010 1200
1
5
8 8 1400 1650
1¾ – 8 1900 2250
1
7
8 8 2550 3000
2 – 8 2800 3300
2¼ – 8 4000 4900
2½ – 8 5500 5800
2¾ – 8 7400 9100
Vue de la page 29