Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11
flowserve.com
Figure 6.4 - Controls Cover Subassembly
6.2.2 Controls Cover Subassembly Remounting
Step 1
Lightly lubricate ‘O’-ring (#7-21) and install around controls cover spigot/pilot (#7-17). Connect all wiring (See section
7 for wiring connection locations). Slide controls cover spigot/pilot into the unit housing insuring not to pinch wiring.
Step 2
Fit the 4 screws (#15-6) into controls cover mounting holes and tighten to torque in section 2.
6.3 Control Modules
Table 6.5 - Control Module Assembly
ITEM NUMBER DESCRIPTION QTY.
14-8 CONTROLS SUBASSEMBLY 1
14-9 SOCKET HEAD CAP SCREWS 3
14-11 BRACKET, CONNECTOR RETAINER 1
14-12 SOCKET HEAD CAP SCREWS 1