Vue de la page 0
1
ZK 313 ASME
Installation Instructions 818542-00
Control Valve
ZK 313 ASME
GESTRA Steam Systems
GESTRA
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - ZK 313 ASME

1ZK 313 ASMEInstallation Instructions 818542-00Control ValveZK 313 ASMEGESTRA Steam SystemsGESTRA

Page 2 - Contents

10Fig. 2ZK 313 ASME-D/20 with actuator PB 1502Technical Data – continued –Dimensions∅ 548∅ 82 d 10350½" BSP357105115Valve lift35734

Page 3 - Contents – continued –

11Fig. 3ZK 313 ASME-E/20 with actuator PB 1502Technical Data – continued –Dimensions∅ 548∅ 82 d 10175½" BSP357175115Valve lift35734115

Page 4 - Important Notes

12200 000100 0008000060000400003000020000100008 0006 0004 0003 0002 000evruCvkseulav1125.133.246.355.568711831902Fig. 4Technical Data – continued –C

Page 5 - Attention

13Fig. 5Technical Data – continued –Capacity Charts ZK 313 ASME, hot water ts-5k9[lb/h][t/h]100 0008000060000400003000020000100008 0006 0004 0003 00

Page 6 - Explanatory Notes

14DesignFig. 6ZK 313 ASME-D/20DHGFIABCZK 313 ASME, straight-through valve

Page 7

15Design – continued –Fig. 7ZK 313 ASME-E/20EHGFIABCZK 313 ASME, angle valve

Page 8 - Technical Data

16KeyAGroove nutBHexagon nut 7/8" – 9 UNC, ASME 18.2.2CUpper part of valveDValve body, straight-through designEValve body, angle designFName plat

Page 9

17ZK 313 ASMEInstallationThe control valve ZK 313 ASME is supplied equipped with or without an actuator and ready forinstallation. If an actuator is m

Page 10 - Dimensions

18Pickling and rinsingThe pipe system of a new installation usually has to be pickled and rinsed before it can becommissioned in order to remove dirt

Page 11

19Retighten the stuffing box H if leaking occurs.ZK 313 ASMEOperationAttention As the stuffing box screw is tightened, the break-away force and the f

Page 12 - Differential pressure

2ContentsImportant NotesUsage for the intended purpose ...

Page 13

20818542-00/305c · © 2005 GESTRA AG · Bremen · Printed in GermanyGreat BritainFlowserve Flow Control (UK) Ltd.Burrel Road, Haywards HeathWest Sussex

Page 14 - ZK 313 ASME-D/20

3MaintenanceZK 313 ASME...

Page 15 - Design – continued –

4Important NotesSafety noteThe control valve must only be installed by qualified staff.“Qualified staff” are persons who are familiar with the procedu

Page 16 - – continued –

5Important Notes – continued –AttentionThe name plate states the technical features of the equipment. A valve without such aname plate must neither

Page 17 - Installation

6DescriptionControl valve for reducing high differential pressures. Application in industrial plants and powerstations as Injection control valve Wa

Page 18 - Commissioning

7Explanatory Notes – continued –FunctionAll pressure parts of the ZK 313 are forged. Internals (incl. seat) are easily exchangeable, even after alon

Page 19 - Maintenance

8Admissible differential pressure1)2)∆ PMX 1 stage [bar] / [psig] 40 / 580∆ PMX 3 stages [bar] / [psig]

Page 20 - GESTRA AG

9Name plate / markingAccording to EN 19 and MSS-SP 25 the type and design are specified on the valve body and the nameplate: Type designation ZK 313