Flowserve PMV D20 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Flowserve PMV D20. Flowserve PMV D20 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Digital Positioner

InstallationOperationMaintenancePMV D20Digital Positioner

Page 2 - Contents

10A = Model noD20 Digital compact positioner, General purpose, LED statusB = Approval, CertificateD General purpose versionI Intrinsically safe versio

Page 3 - 1. General information

114.5 Control DrawingUNCLASSIFIED AREAIsolatorIsolator4+PostitionerIi : 29,7mAPi : 79mWCi : 40 nFUi : 10,6VHAZARDEOUS AREA7+6-PositionerUi : 10,6VPi :

Page 8 - 4.2 Mechanical switches

16The PMV D20 positioner is a digital posi-tioner with various options. The positio-ner consists of three main modules:1. The microprocessor-based ele

Page 9 - 4.3 Type sign

176.1 GeneralBefore starting installation, inspect the di-gital positioner for any transit damages.The PMV D20 positioner is installed with amounting

Page 10 - 4.4 D20 Model Code

18For mounting, proceed as follows:Mounting the Follower Arm (Figures 3and 6)1. Unscrew the lock nut for the followerarm attachment.2. Place the follo

Page 11 - 4.5 Control Drawing

19follower pin farther out on the feedbacklever to reduce the angle of rotation.NOTE: Stroke the actuator carefully andensure the follower arm does no

Page 12 - 4.6 Certificates

2 Contents1. General information ... 3 1.1 Using ...

Page 13

20Rotary actutaors VDI/VDE 3485(Namur)Mount bracket 1 to positioner. Securewith 4 x M6 screws 2.Fit positioner on actuator and securewith 4 x screws

Page 14

21Figure 4. Basic Adjustment for a Linear Pneumatic ActuatorMounting A Mounting BFigure 5. Yoke Actuator Mounting(according to IEC 534 par

Page 15

22Figure 7. Mounting a Part-turnValve Actuator in acc. with VDI/VDE384512 3After mounting has been completed,tube the positioner to the actuator usin

Page 16 - 5. Principle of operation

238.1 Grounding screwThe grounding screw, located inside thepositioner cover, should be used to prov-ide the unit with an adequate and reliableearth g

Page 17 - 6. Mounting and installation

24The PMV D20 digital positioner has beendesigned to operate correctly inelectromagnetic (EM) fields found intypical industrial environments. Careshou

Page 18

259. OperationCalibrationbuttonALARMOPEN/CLOSEDCONTROLLING9.1 GeneralThe D20 is operated by the yellow button.Depending on desired action, press theb

Page 19 - 6.3 Rotary actuators

26x39.4 Set of Direct or Reverse actionNote! For safety reason, this opera-tion has to be done max 5 minutesafter calibration. If time has run ou

Page 20

27Button functions:Press 5 sec = CalibrationPress x3 = Direct/reverse actionPress x4 = Show gain settingPress x5 - x11 = Change gain

Page 21 - (according to IEC 534 part 6)

28 10. Limit switches & 4 - 20 mA transmitter (Optional)Caution!The installation of electricalequipment in hazardous areas mustcomply with the pr

Page 22

29• Press and hold button while switchingon power to the D20, keep the buttonpressed for 6 sec. The eeprom will nowbe erased, and then all three LEDs

Page 23 - 8.1 Grounding screw

31.1 UsingThe following instructions are designedto assist in unpacking, installing andperforming maintenance as required onFLOWSERVE products. Produc

Page 24 - 8.3 Compliance voltage

30 11. Trouble shooting11.1 PMV D20 Normal operation11.2 PMV D20 error codesAn unsuccessful calibration is indicated by the LED:s. The type of erro

Page 25 - 9. Operation

3111.3 PMV D20 symptoms and solutions Failure Probable Cause Corrective action No LED is flashing. Current source below 3,6 mA . Verify current sou

Page 26 - 9.5 Show gain setting

3212. Spare parts12111615 191817 121 214 3 5 8 79 4

Page 27 - 9.6 Change of gain setting

33POS PMV P/N Description RemarksN/AEEx iaHARTEEx ia, Hart12334455557891112141414141414141

Page 28 - 10.4 Installation

Palmstierna International ABKorta Gatan 9SE-171 54 SolnaSWEDENTel: +46 (0) 8 555 106 00Fax: +46 (0) 8 555 106 01E-mail: [email protected]

Page 29 - 10 11 12

41.3 Protective clothingFLOWSERVE products are often usedin problematic applications (e.g.extremely high pressures, dangerous,toxic or corrosive mediu

Page 30 - 11. Trouble shooting

5WARNING:Before products are returned toFLOWSERVE for repair or serviceFLOWSERVE must be providedwith a certificate which confirmsthat the product has

Page 31

6is higher than the maximum actuatorpressure rating a supply regulator isrequired to lower the pressure to theactuator’s maximum rating (not to beconf

Page 32 - 12. Spare parts

7 4. SpecificationsInput signal 4-20 mACurrent supply min. 3,6 mACurrent supply Max. 150 mALoad Standard 400 ohm at 20mALoad HART 470 ohm at 20mAVolt

Page 33

84.2 Mechanical switchesType SPDTSize Sub Sub miniatureRating 3A, 125 VAC / 2A, 30VDCMechanical life >1 x 106 operationsNamur sensorsType P+F NJ2 V

Page 34 - FCD PMENIM0012-01

9Operating time 1.0 msTransmitterPower supply 12-28 VDCOutput 1-22 mAResolution 0.1%Linearity ±0.5%Load impedance 600 ohm at (12 VDC and 20mA)Alarm Ou

Commentaires sur ces manuels