4.4 If the seal is mounted directly on the shaft, rather than on the equipment sleeve, install
the impeller spacer sleeve (possibly modied).
4.5 Install the impeller and case.
4.6 Make any necessary impeller adjustments.
Warning: Loosen the bearing assembly and drive belts only enough to make the
adjustments. Fully retighten the bearing assembly and belts after adjustment.
6
4.3 It is advisable to hold the gland gasket in place in the gland groove with contact
adhesive, #404 “super glue” (in spots only), or vacuum grease. With the seal clamp
collar facing toward the bearing assembly, slide the complete cartridge over the
pump shaft/sleeve and push back into the pump case. See Figure 9.
Warning: Do not hammer on or push against the cartridge sleeve.
Do not secure the gland retaining screws to the equipment casing at this time.
Check Seal Chamber Concentricity Figure 8
0.38 mm (0.015") Maximum Seal
Chamber Concentricity Runout
Inserting Cartridge Figure 9
Push on Gland to Slide the
Seal over the Shaft/Sleeve
Do Not Hammer or
Push on Seal Sleeve
Do Not Hammer or
Push on Seal Sleeve
Push on Gland to Slide
the Seal over the Shaft/Sleeve