Notice: Cleanliness during installation is crucial to the satisfactory
operation of the MSS seal.
Caution: Installation of this seal requires the use of an adhesive to bond
the O-ring secondary seals together. Do not allow the
adhesive to come in contact with skin.
There are two basic models of the MSS seal, Piloted, see Figure 2,
page 4, and Non-Piloted, see Figure 3, page 8.
Seal Chamber Requirements Figure 1
Face of seal housing to be square to the
axis of the shaft to within 0.5 mm (.020 inch)
FIM and have a 1.6 mm (63 m inch) R
a
nish or better
A
J
B
Sleeve or
shaft nish
to be 0.8 mm
(32 m inch)
R
a
or better
Shaft or Sleeve
OD ±.02 mm
(±.001 inch)
Bearings must be in good condition
Maximum axial movement of shaft (end play) = 0.25 mm (0.010inch) FIM
Maximum combined shaft eccentricity and shaft deection at face of housing
total = 3.8 mm (0.150 inch) FIM