Experience In MotionUSER INSTRUCTIONSInstallationOperationMaintenanceLimitorque Automax CEA SeriesFCD AXENIM2080-00-AQ – (01/15)
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1410Basic Menu Calibrate Setup ProStatusProtectionShiftReadMan/AutoCalibrateRotation
11Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.com3. Installation and OperationDescriptionFlowserve CEA actuators are
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1412with two Belleville washers (except 8”, 10” 82/83 and 10” 51/52) and replace ret
13Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.com4.2 Gear TrainA precision cut bronze or ductile iron worm gear set d
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1414Analog Output Available option will provide analog 4-20mA continuous position fe
15Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comMenu IndicatorThere are indicators at both sides of the display wind
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1416The menu contents are shown in the figures on the right and the texts are describ
17Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comBASIC MENU /STATUSThe Status Menu is used to select whether or not t
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1418BASIC MENU READValues can be read using the Read Menu and some values can be res
19Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comBasic Menu Outputs - Expanded ViewOutputs1(Pos/Alarm) 2(Pos/Alarm)3
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/142
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1420Valve Actionno actiongo to closego to openmanualMotor TempON/OFFMin Tempdegrees
21Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comBasic Menu Calibrate/Outputs/Alarms/Compartment Temp>>>>
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1422Magnet Puck Adjustment If for any reason the black plastic EMC/EMI controls cove
23Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comPerformance SpecificationsActuatorOutput Torque(ContinuousStart/Run T
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1424Symptom ResolutionActuator is commanded to move but does not move.1. Use hand w
25Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comITEM NO. PART NUMBER DESCRIPTION QTY. ITEM NO. PART NUMBER DESC
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/1426ITEM NO. PART NUMBER DESCRIPTION QTY.15-7 DY101937A Cover, Terminal, CEA, 15
27Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.com
flowserve.comTo find your local Flowserve representative or for more information about Flowserve Corporation, visit www.flowserve.com.FCD AXENIM2080-00
3Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comContents1. Important Notes 52. Actuator Quick Start Guide for C-PR
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/144Using Flowserve Valves, Actuators and AccessoriesGeneral UsageThe following instr
5Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comStorageIn many cases, Flowserve products are manufactured from stainl
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/146Normally there are no orientation restrictions for actuator mounting; consult fac
7Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.comC-MOD versionThe C-MOD or Modulating control actuator ships from the
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/148C-PRO WiringON/OFF with Isolated Voltage Command ControlC-PRO WiringON/OFF with N
9Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14flowserve.com2.2 Menu TreeC-PRO & C-MOD Menu Tree - SW120Basic Menu* Standard
Commentaires sur ces manuels