McCANNA Valves
1. Installation
These valves may be installed in any position. The installation of these
flanged end valves require no special instruction
just the use of
good pipe fitting practices. Flanges conform to ANSI Standards B16.5
1988 Class 150 (ERP1 or EFP1) or Class 300 (ERP3).
2. Stem Seal Adjustment
If leakage is evident in stem packing area, tighten the adjusting nut
1
/
4
turn. If leak still persists, repeat above. Replacement of stem seals
(10) is indicated if the leak is still apparent after
1
/
2
turn.
3. Disassembly for Seal Replacement
aWARNING: Begin with the valve partially open in a depressurized line.
A. Remove flange bolts and nuts (not provided) and lift body (11)
from line for servicing.
IM002G
E-Series Unibody Flanged End Ball Valves
Models EFP1:
1
/
2" – 1
1
/
2"; ERP1: 2" – 4"; ERP3: 1
1
/
2" – 4"
Installation, Operation and Maintenance Instructions
Item Description
1 Handle
2 Stem
3 Stop Pin (not shown)
4 Handle Retainer Nut
5Travel Stop (1" and larger only)
6 Gland Ring
7 End Adaptor
8 Ball
9Seat (2)
10 Stem Seals
11 Body
12 End Seal
13 Grounding Washer
14 Adjusting Nut
15 Seat Socket (
1
/
2" – 1
1
/
2" EFP1 & 2" ERP1 only)
16 Spacer Seal (
1
/
2
" – 1
1
/
2
" EFP1 & 2" ERP1 only)
12
8
11
9
13
6
1
4
2
14
5
Sizes
1
/
2" – 1
1
/
2" — Full Port CLASS 150 - EFP1
Sizes 2" – 4" — Regular Port CLASS 150 - ERP1
Sizes 2" – 4" — Regular Port CLASS 300 - ERP3
7
10
16
15
12
8
11
9
13
7
6
1
4
2
14
5
10
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 2. Stem Seal Adjustment

McCANNA Valves1. InstallationThese valves may be installed in any position. The installation of theseflanged end valves require no special instruction

Page 2 - 4. Reassembly

NOTE: Care should be taken to avoid scratching or damaging gasketsurface on flange face.B. Unscrew end adaptor (7) from body (11) by using hex nut or

Page 3 - 5. Testing

Flow Control DivisionMcCANNA ValvesIM002G 3F. Temporarily thread the end adaptor (7) into the body (11) using ahex nut or hexagonal bar (dimensions ar

Page 4 - McCANNA Valves

NOTICE: McCANNA Valves are designed and manufactured using good workmanship and materials, and they meet all applicable industry standards. Flowserve

Commentaires sur ces manuels

Pas de commentaire