Installation
Instructions
Experience In Motion
Cartridge dual pusher seal for
standard and big bore ANSI pumps
Durametallic
®
P-200
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Instructions

Installation InstructionsExperience In MotionCartridge dual pusher seal for standard and big bore ANSI pumpsDurametallic® P-200

Page 2 - Figure 1

104 OperationFollowingtheserecommendationswillensuremaximumMTBPMoftheP-200 seal.4.1 Do not exceed corrosion limits. The P-200 is designed to

Page 3 - P-200 Dimensional Data

5 RepairThis product is a precision sealing device. The design and dimension tolerancesarecriticaltosealperformance.OnlypartssuppliedbyFlows

Page 4

TOREORDERREFERTOB/M#F.O.FIS111eng 10/13 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve Corpo

Page 5 - 2 P-200 Seal Installation

2DescriptionThis P-200 seal is a dual, cartridge mounted, end face mechanical seal, designed for ease of installation. No seal setting dimensions are

Page 6 - 3 Piping

Dimensional Data for P-200 Seal, inch3P-200 Dimensional Data Figure 2*ThissealsizeusestheN-CBRinnersealrotaryunit.†Preferreddesignfort

Page 7 - Rotation

1.2 Disassemble equipment in accordance with equipment manufac-turer’s instructions to allow access to seal installation area.1.3 Remove existing me

Page 8

5Install pump backplateFigure 32 P-200 Seal Installation Tools needed: • Open-end wrench for gland nuts • Allen wrenches provided  • Silicon

Page 9 - PipingPlan11/52

62.3 Position the P-200 cartridge gland withtheglandgasketinplaceagainstthepumpbackplate(sealchamber/stufngbox)face,installatwashe

Page 10 - 4 Operation

7Shaft Rotation from Exposed End of Gland Figure 4Clockwise Rotation(CW) (mostANSIpumps)Inlet Port c Outlet  Port b Cou

Page 11 - 5 Repair

3.3 For dual pressurized seal (double seal) operation, supply a clean compatiblebarrieruidtotheinletportatapressureatleast170kPa(25p