5
Step 7 Observe the length of the
lock pin outside of the gland.
The pin should extend 2.5 to
4.8 mm (0.10 inch to 0.19 inch)
from the gland. If it is more or
less than this, remove the gland
and recheck the installation.
Step 8 Pry off the centering devices
with a screwdriver.
Step 9 Connecttheushline to the gland if required.
Step 10 Turn the shaft by handasanalchecktobesurenothingisbinding.