2.9 SetthebackofthespringholderatreferencemarkB,Figure1,
andtightensetscrewsrmlyandevenly.Therotatingcomponent
assemblyisnowintheproperpositiontoprovidethecorrectsetting
andspringcompressionfornalassembly.
2.10 Wipe the seal facescleanwithalcoholbeforecompleting
equipmentassembly.Sealfacesshouldnotbelubricated,but
shouldbeleftcleananddry.
2.11 Assemble the pump.
2.12 Position the gland tothefaceofthesealhousing.Besurethe
glandpilotisproperlyengaged.Tighten the gland stud nuts
evenly,crossstaggertheadjustmentofthenuts.Followthe
equipmentmanufacturer'srecommendationsforglandstudnut
torque.Intheabsenceofrecommendations,glandnutsshould
onlybetorquedtoestablishaleaktightsealattheglandgasket.
Properglandboltadjustmentisespeciallyimportantwithclamp
stylestationaryfaceswhereexcessivetorquemaydamagethe
face.
2.13 See Operational Recommendationsbeforestartingpump.
3 Double Suction and Multistage Horizontal Split
Case Pumps (2 boxes)
3.1 Scribe mark A ontheshaftorsleevetolineupwiththefaceof
thesealhousing.
3.2 Scribe mark B atthesealsettingpointshownenclosedina
rectangularboxontheassemblydrawingincludedwiththe seal.
Thissealsettingdimensionismeasuredfromthefaceofthe
sealhousingtothebackofthespringholder.Thebackofthe
springholderwillbelocatedatthispoint.
3.3 Lubricate the shaftorsleevelightlywithsiliconelubricant
providedwiththesealbeforeinstallinganysealparts.
3.4 Install the rotating face gasketintotheboreoftherotatingface.
3.5 Install the rotating seal componentsontheshaftorsleeveinthe
propersequence.HandlePTFEU-cupringsandDuraterotating
facegasketswithextremecare.PTFEU-cupringsmustbe
assembledindividuallyandnotpushedontheshaftorsleevewhile